3.4 Setup for In-band Management
To perform an in-band management, it is necessary to connect the system to your TCP/IP network. The steps are:
1. Configure IP and SNMP related settings to the system using direct console management the first time the
system is being installed.
2. Find a proper straight-through Category 5 UTP cable (maximal length 100 meters) for the connection.
3. Connect one end of the UTP cable to the UTP port on the SNMP module and connect the other end to the
device, such as a switching hub, in your TCP/IP network.
4. Start your in-band management operations. For different management methods, refer to:
Chapter 4 for Telnet management
Chapter 5 for SNMP management
Chapter 6 for Web management